BBB Accredited Business with A+ Rating badge
NATE Certified – North American Technician Excellence badge
Authorized Lennox Premier Dealer – top-tier HVAC products and service
Daikin logo – heating and air conditioning manufacturer
Goodman Air Conditioning & Heating logo
Carrier – heating and air conditioning brand logo
Trane – heating and air conditioning brand logo
Bryant Heating & Cooling Systems logo
Cozy living room with modern fireplace, plush sofa, natural light, and stylish decor.

Heating, Cooling, & Fireplace Services in Draper

Maintaining a comfortable and efficient home requires dependable and skilled service. For homeowners in Draper, Comfort Solutions delivers top-notch heating, cooling, plumbing, and fireplace services. From urgent repairs to routine maintenance, we ensure quality and reliability all year.
Book Now

HVAC Services In Bountiful

Our seasoned technicians provide prompt and reliable service for various heating and cooling systems.

Furnace Maintenance

Keep your system running smoothly throughout the winter with routine inspections and tune-ups offered through our furnace maintenance services in Bountiful.
Learn More

Furnace Repair

Address heating problems quickly and effectively with our trusted furnace repair solutions.
Learn More

Furnace Replacement

Upgrade to a high-efficiency furnace for improved comfort and energy savings with our professional furnace installation services.
Learn More

Air Conditioner Maintenance

Extend the lifespan and performance of your cooling system with routine maintenance as part of our comprehensive AC services.
Learn More

Air Conditioner Repair

Get your air conditioning system back on track with fast and effective AC repair from our skilled team.
Learn More

Air Conditioner Replacement

Modernize your home’s cooling with energy-efficient air conditioning installation from Comfort Solutions.
Learn More

Specialized Fireplace Services in Draper

  • Fireplace Inspections & Maintenance: Keep your fireplace in optimal condition with professional inspections and regular maintenance to identify and address potential issues early.
  • Fireplace Repairs: Our reliable repair services ensure your fireplace remains safe and functional whether it's a faulty igniter or a damaged part.
  • Custom Fireplace: Design a unique focal point for your living space with a personalized custom fireplace crafted to suit your home’s aesthetic.
  • Fireplace Showroom: Visit our showroom in Draper, to explore a variety of modern and traditional fireplace designs and receive advice tailored to your preferences.
Book Now
Warm indoor pellet stove for cozy heating comfort.
Fireplace burning firewood, fire flames on wood logs, bricks background. Cozy warm home

Specialized Fireplace Services in Draper

A well-cared-for fireplace can enhance your home's warmth, beauty, and overall value. Comfort Solutions offers a full range of fireplace services in Draper, to keep your fireplace working safely and looking great.
Book Now

Recent Jobs and Reviews in Draper, UT

Rated 4.8 out of 5 stars based on 5 customer reviews

Job Locations and Reviews

Performed comprehensive system evaluation on 22-year-old residential air conditioning unit experiencing inadequate cooling capacity and refrigerant issues. Assessed condenser functionality, documented failed compressor unable to maintain proper cooling performance, and identified refrigerant system deficiencies. Photographed existing equipment installation including outdoor disconnect, electrical connections, and condenser unit placement. Provided replacement estimate for complete system upgrade due to age and extent of component failure.
Performed comprehensive system evaluation on 22-year-old residential air conditioning unit experiencing inadequate cooling capacity and refrigerant issues. Assessed condenser functionality, documented failed compressor unable to maintain proper cooling performance, and identified refrigerant system deficiencies. Photographed existing equipment installation including outdoor disconnect, electrical connections, and condenser unit placement. Provided replacement estimate for complete system upgrade due to age and extent of component failure.
Aaron B.
Aaron B. Checked in
Performed comprehensive system evaluation on 22-year-old residential air conditioning unit experiencing inadequate cooling capacity and refrigerant issues. Assessed condenser functionality, documented failed compressor unable to maintain proper cooling performance, and identified refrigerant system deficiencies. Photographed existing equipment installation including outdoor disconnect, electrical connections, and condenser unit placement. Provided replacement estimate for complete system upgrade due to age and extent of component failure.
Draper, UT 84020
Responded to service call for three ductless mini-split units displaying flashing service indicators and blowing warm air only. Units were located in two bedrooms and living room on west side of residence, approximately 4-5 years old. Upon arrival, observed wall-mounted indoor heads with one unit displaying "P6" error code on digital display. Performed diagnostic evaluation of all three affected mini-split systems to identify cause of malfunction and warm air discharge. Documented equipment condition through photographic records showing installed indoor air handlers and error code display for service records and further analysis.
Responded to service call for three ductless mini-split units displaying flashing service indicators and blowing warm air only. Units were located in two bedrooms and living room on west side of residence, approximately 4-5 years old. Upon arrival, observed wall-mounted indoor heads with one unit displaying "P6" error code on digital display. Performed diagnostic evaluation of all three affected mini-split systems to identify cause of malfunction and warm air discharge. Documented equipment condition through photographic records showing installed indoor air handlers and error code display for service records and further analysis.
Ray R.
Ray R. Checked in
Responded to service call for three ductless mini-split units displaying flashing service indicators and blowing warm air only. Units were located in two bedrooms and living room on west side of residence, approximately 4-5 years old. Upon arrival, observed wall-mounted indoor heads with one unit displaying "P6" error code on digital display. Performed diagnostic evaluation of all three affected mini-split systems to identify cause of malfunction and warm air discharge. Documented equipment condition through photographic records showing installed indoor air handlers and error code display for service records and further analysis.
Draper, UT 84020
Responded to no cooling complaint on 8-year-old single-zone system with outdoor unit located on north side of property. Customer reported air handler running but outdoor fan motor humming without rotation. Upon inspection, found condenser fan motor seized and drawing elevated amperage at 6.01A as confirmed with digital clamp meter. Tested capacitor and electrical connections at outdoor unit contactor assembly. Diagnosed failed condenser fan motor preventing heat rejection and causing loss of cooling capacity. System restored to proper operation with outdoor fan motor spinning freely and unit cycling normally.
Responded to no cooling complaint on 8-year-old single-zone system with outdoor unit located on north side of property. Customer reported air handler running but outdoor fan motor humming without rotation. Upon inspection, found condenser fan motor seized and drawing elevated amperage at 6.01A as confirmed with digital clamp meter. Tested capacitor and electrical connections at outdoor unit contactor assembly. Diagnosed failed condenser fan motor preventing heat rejection and causing loss of cooling capacity. System restored to proper operation with outdoor fan motor spinning freely and unit cycling normally.
Solomon V.
Solomon V. Checked in
Responded to no cooling complaint on 8-year-old single-zone system with outdoor unit located on north side of property. Customer reported air handler running but outdoor fan motor humming without rotation. Upon inspection, found condenser fan motor seized and drawing elevated amperage at 6.01A as confirmed with digital clamp meter. Tested capacitor and electrical connections at outdoor unit contactor assembly. Diagnosed failed condenser fan motor preventing heat rejection and causing loss of cooling capacity. System restored to proper operation with outdoor fan motor spinning freely and unit cycling normally.
Draper, UT 84020
Review
Solomon was very thorough and prompt, truly professional.
Clissold - Draper, UT 84020
Review
Excellent !
Tschetter - Draper, UT 84020
Review
Excellent service
Tschetter - Draper, UT 84020
Review
Excellent service !
Tschetter - Draper, UT 84020
Review
Tyler was very polite and professional. He explained my options clearly, established expectations, worked cleanly and efficiently, returned my fireplace to good working order, and left me with what looks like a brand new fireplace. I am beyond impressed!
Burnham - Draper, UT 84020